HYDROGEN VIGIL: CHS-HTR-PH-100-5V-CM
FOR STATIONED AND AUTOMOTIVE APPLICATIONS
  
CHS-HTR-PH-100-5V-CM is an input device compatible for HY-102D (R3), H2CON-6, Digital Transmitter FFM-066 or user interface
-
The transducer houses a solid state electrochemical sensor which directly, specifically and intelligently measures hydrogen gas presence in surrounding gaseous fluid medium, along with, head on pre-amplifier, to output 0 to 5 Volts control signal for FS and is intrinsically safe to Exia-IIC.
-
The sensor is housed in Teflon and the transducer housing is metallic, chosen from among Aluminum, LM-6, HE-30 or SS-304/316, to suit the environment.
-
The measuring capability is direct and is not based on co-relation methods.
-
In-built heaters are not required and most importantly, it does not suffer any consequence due to high hydrogen exposure, a crucial feature in safety applications.
-
Ideal for ceiling mounting, on panel that may be readily available or designed.
-
Separate Calibration system is available and transducer design is compatible for in-situ attempts, in a user friendly way.
SPECIFICATIONS OF HYDROGEN VIGIL - CHS-HTR-PH-100-5V-CM
|
1
|
Transducer
|
3 Wires in metal housing containing sensor and Pre-amplifier. Intrinsically safe. Exia II-C.
|
2
|
Specificity
|
Specific & selective only to Hydrogen.
|
3
|
Sensor Technology
|
Solid State Electrochemical Cell (Direct Partial Pressure Measurement of Hydrogen in gaseous Fluid based on Proprietary Indian Patent No. 252998 w.e.f 14/06/2007).
|
4
|
Dimensions
|
Ǿ 31.5 x 76mm to flanged head Ǿ45 x 12mm.
|
5
|
Transducer Power
|
12Volt DC( ±10%), 1mA or 20 to 30Volt DC(available on request).
|
6
|
Transducer Receptacle
|
Round connector (F).
|
7
|
Sampling
|
By Diffusion. Aperture Φ 2mm.
|
8
|
Output (Control Signal)
|
0 to 5V DC. Ambient: 0V(±5mV), N% H2 in Air = 5V(±5mV), N=1 to 5. FIne tuning through respective pot for span and zero respectively.
|
9
|
Response Time
|
< 3 seconds
|
10
|
Accuracy
|
±10 % FSD
|
11
|
Max O/P current (OP-AMP)
|
< 0.5Ma
|
12
|
Compatible Interface
|
CHS-HY-102D (R3)
H2CON-6
FFM-066
PLC, DCS, BMS, etc. (USER INTERFACE)
|
13
|
Connectivity
|
Round connector (M) at one end, 2-core Teflon-Teflon shielded (SPC) 7/34” cable and Interface compatible connector at other end.
|
14
|
Mounting
|
Ceiling mounted on available or designed panel, through fixing screws x 3 nos., at 37.5 PCD. Minimum distance between false ceiling and roof should be 150mm. Recess in false ceiling 32Ǿ.
Separate fixing brackets available optionally.
|
Specification subject to changes without prior notice, due to continuous R&D and development of Company’s Products. |